Xled-3-VARbright top illumination

  • Standard sizes d 100 and d 200 mm Light emission
  • Bright matrix system with collimator foil for high luminous efficiency
  • Integrated controller and switching inputs for continuous and flash operation
  • Aluminum housing with 20 mm overall height
  • Pulse-pause monitoring
  • flash time limited to 1.5 ms

Find out more ...

Xled-3-VAflat and bright incident­lighting for large areas

  • Standard sizes from 220 x 220 to 820 x 820 mm light emission
  • Edge lighting system with brightness levels up to 240,000 lx
  • Integrated controller and switching inputs for continuous and flash operation
  • Flat aluminum housing with 20 mm overall height
  • Pulse-pause monitoring, flash time limited to 1.5 ms, 1-10 V interface

Find out more ...

robust
for the industrial sector

fast
response time

up to 1.7 million lx
in flash mode

flat
design

Incident lighting according to customer specifications

Genau hier liegt unsere Stärke. Durch dem planistar die Leuchten im eigenen Hause fertigt, können wir kundenspezifische Hintergrundbeleuchtungen in kurzen Lieferzeiten herstellen.

So müssen Sie sich nicht nach unserem Standardprogramm richten. Wir richtigen uns genau nach Ihren Anforderungen und den Gegebenheiten vor Ort.

So sparen Sie Kosten in der
  • Konzeption der Anlage,
  • Konstruktion und in der
  • Auswertung in der industriellen Bildverarbeitung.

Unsere Fertigungsabläufe sind so geplant, dass eine kundenspezifische Leuchte nahezu den gleichen Durchlauf hat wie eine Standardbeleuchtung. Der einzige Unterschied ist, dass die Sonderleuchte genau Dokumentiert wird. So sind wir auch noch nach Jahren in der Lage, Ersatz zu liefern.

Profitieren Sie von der Zusammenarbeit mit planistar.
Leuchten direkt vom Hersteller

Sustainability at

When revising our product series, we always take sustainability into account, as many little things add up to a big picture. 

This starts with saving resources and energy, the right choice of materials we use, right through to packaging and disposal.
 

  • Raw materials are selected with care
  • Optimization of electronics and thermal management to extend service life
  • Manufacture of lights and electronics in Germany
  • Reduction of raw materials with the same properties
  • All materials can be recycled at the end of their service life
  • Packaging is 100% recyclable

 

Find more information on sustainability here

Why choose LED area lighting from planistar?

Thanks to our many years of experience in the development and production of lighting technology for a wide variety of areas, we have been able to continuously optimize our LED luminaires and adapt them to the increasing requirements of our customers.

Lighting technology

Most of our lighting works with edge lighting and a light guide. As planistar had the patent for the edge lighting of light sources and light distribution using a dot grid, we also have the knowledge to calculate and produce any size.  

Our surface light guides have the advantage of maintaining uniform light distribution over the entire service life. The failure of an LED row in the edge area has virtually no effect on the uniformity in the measuring range. With a matrix system, on the other hand, a dark spot is immediately visible.

For some applications, however, a conventional matrix system is more suitable. Thanks to our sophisticated design of these lights, we can also supply you with devices with good homogeneity and very high light intensity. These reflected lights for image processing are usually very bright, making it possible to reduce motion blur with short exposure times.
 

Electronics continuous and flash mode

In our LED light fittings, the LED controllers are always built into the lights. This prevents operating errors and accidental damage.

In order to achieve optimum interaction between the LED and the control unit, the electronics are also developed in-house and manufactured exclusively for us by a regional company. 

The installation of the controller in the fitting offers a decisive advantage, especially for applications with flash operation. The very high and short flash current is generated and stored in the luminaire. The currents in the supply line can thus be reduced accordingly. This principle helps to reduce the risk of EMC interference.

The internal microcontroller monitors the pulse-pause ratio and only allows a new pulse after 1:5. This prevents the LEDs from overheating and being damaged by the flash mode.

Thermal management

The days when LEDs did not generate any heat are long gone. Due to increasingly powerful technology, it is important to ensure optimum heat management for the entire luminaire. 

Because the only death for an LED is heat death. For this reason, the heat at the LEDs determines the service life of the entire luminaire.

Our mostly 2 mm aluminum housings serve as a large cooling surface, which can be supported by additional heat sinks depending on the application.

Any questions?

Our team will be at your disposal for any questions you may have. We will process your request as soon as possible.

+49 (0) 9364 8060-0 sales@no-spam.planistar.de   Catalog incl. prices
Office hours:  
Monday - Thursday 8.00 am - 04.00 pm
Friday 8.00 am - 01.00 pm
   

Accessories incl. prices

You can also find us at:Logo XING Logo Linkedin